DESCRIPTIONThis instrument is designed to be extremely accurate, fast and simple to use in diverse water quality applications. Advanced features include the ability to select from 3 different solution types that model the characteristics of the most commonly encountered types of water; proprietary temperature compensation and TDS conversion algorithms; highly stable microprocessor-based circuitry; user-intuitive design; and waterproof housing. A true, one-handed instrument, the PT1 is easy to calibrate and easy to use. To take a measurement, you simply press a button then dip the pen in solution. Results display in seconds.
SPECIFICATIONS
PT1 FUNCTIONS
Mode
Parameter
Solution Model
Units
Cond KCl
Conductivity
potassium chloride
microsiemens (µS)
tdS 442
Total Dissolved Solids (TDS)
442™ Myron L Natural Water Standard
parts per million (ppm)
tdS nacl
TDS
sodium chloride
ppm
SALt 442
Salinity
442™ Myron L Natural Water Standard
parts per thousand (ppt)
SALt nacl
Salinity
sodium chloride
ppt
Specifications
Measurement Range
1 - 10000 µS or ppm (0.0010 - 10.000 ppt salinity)
Accuracy (After Wet Calibration)
± 1% of reading
Repeatability
< 1000="" µs="" or="" ppm="" ±="" 1="" />
≥ 1000 µS or ppm ± 0.3% of reading
Resolution
Conductivity and TDS:
0.1 for 1.0 - 99.9 µS or ppm
1 for 100 - 10000 µS or ppm
Salinity:
0.0001 for 0.0010 - 0.1000 ppt
0.001 for 0.100 - 10.000 ppt
Temperature:
0.1 ºC / 0.1 ºF
Time to Reading Stabilization
10 - 20 seconds
Active Mode Power Consumption
30 - 100 mA
Sleep Mode Power Consumption
2 µA
Temperature Measurement Range
0 - 71 °C or 32 - 160 °F
Temperature Accuracy Displayed
± 0.1 ºC or ± 0.1 ºF
Temperature Compensation Method
Automatic to 25 ºC
Physical Dimensions
17.15 cm L x 1.59 cm D or 6.75 in. L x .625 in. D
Weight
55 g or 1.94 oz.
Case Material
Anodized Aircraft Aluminum with Protective Coating
Battery Type
One N type, Alkaline, 1.5V
Calibration Solution Point
1800 µS KCl; 3000 ppm 442™ (2027 ppm NaCl)
Operating/Storage Temperature
0 - 55ºC or 32 - 131ºF
Water Resistance
IP67 and NEMA 6
EN61236-1: 2006 - Annex A: 2008
Electrostatic discharge to the PT1 may cause it to spontaneously turn on. If this
occurs, the PT1 will turn off.
Tech Specs
Test Equipment General Attributes
IP Rating
IP67
Product Weight
1.94 LBS
Product Height
2.30 IN
Product Length
6.75 IN
Product Width
3.50 IN
HTS/Schedule B Number
9030.31.0000
ECCN Number
EAR99
Battery Type
Other
Power Supply Voltage
Battery Powered
Country of Origin
United States