-40%

LCM Smart Electronic Load Constant Current Electronic Battery Tester 150V 10A

$ 21.11

Availability: 10 in stock
  • Return shipping will be paid by: Buyer
  • All returns accepted: Returns Accepted
  • Marca: - Senza marca/Generico -
  • Marke: Markenlos
  • Operating temperature: -10~60℃
  • EAN: Does not apply
  • Manufacturer Part Number: Does not apply
  • Consumption: <1.5A
  • Size:: 149×96×80mm/195×105×135mm(package)
  • Display screen: LCM display
  • Country/Region of Manufacture: China
  • Numéro de pièce fabricant: Non applicable
  • Brand: Unbranded
  • Qty: 1Pc
  • Marque: - Sans marque/Générique -
  • Restocking Fee: No
  • select: 15W 150V Electronic Load Resistor
  • Condition: New
  • Model:: Does not apply
  • Refund will be given as: Money Back
  • MPN: Does not apply
  • UPC: Does not apply
  • Item must be returned within: 60 Days
  • .Power Voltage: DC6~12V

    Description

    Welcome to memolines, happy shopping!
    Shop Homepage
    New product
    Feedback
    About us
    Specifications:
    PowerVoltage:DC6~12V Interface:DC5.0
    Voltage measure range:0~150V Accuracy:0.05V
    Current adjustable range:0~10A Accuracy:0.05A
    Capacity range:0~999.999Ah Accuracy:0.001Ah
    Cumulative range:0~99999.9Wh Accuracy:0.01Wh
    Measure range:0~2999.9W Accuracy:0.01W
    Impedance range:0~999.9Ω Accuracy:0.01Ω
    Temperature range:0~99℃ Accuracy:1℃
    Max timing :999:59:59 Accuracy:1s
    Fan cooling power:<150W
    Fan control threshold:Temp>40℃
    Standby reminder threshold:<2W/0.5h;
    Timing function:>0.5W start timing
    Input interface: 20A high current occlusion screw column, type A USB,Mini USB, Micro USB, Type-C USB
    Refresh time:>500ms/time
    Measurement rate: 0.5time/s
    Over limit alarm: interface warning and buzzer alarm
    Voltage overrun auto- stops discharge range:0~150V
    Current overrun auto- stops discharge range:0~10A
    Power overrun auto- stops discharge range:0~150W
    Display screen: LCM display
    Size:149×96×80mm/195×105×135mm(package)
    Weight:570g(package)/370g(net weight)
    Consumption:<1.5A
    Operating temp:-10~60℃
    Operating humidity:10~80(No condensation)
    Mode button function description
    :
    1. Click to switch each display interface
    2. The function of the button operation in the 2-4 interface is as follows:
    ①long press all records to clear;
    ②Double-click capacity (Ah) to reset to zero;
    ③three-stroke power (Wh) reset to zero;
    ④four-stroke power (00:00:00) reset to zero;
    ⑤consecutive seven hits at no load, making the current zero accurate in the current temperature environment.Calibration is zeroed for accurate measurement at low currents;Factory reset all parameters.
    3. The operation functions of the buttons under the interfaces 6, 7, 9, 11, and 13 are as follows:
    ①Double-click the parameter value to increase, double-click and long press the parameter to continue to increase;
    ②The value of the three-stroke parameter is reduced, and the length of the three-stroke is continued to decrease.
    How to use
    :
    1. Input voltage × current ≤ 150W;
    2. Turn on the load power supply, and the coarse and fine adjustment knobs will be reset to zero (counterclockwise to the end)
    3. Long press the mode button to clear all data;
    4. Connect to the power supply under test, and use the fine adjustment knob to slowly adjust the discharge current.When the fine adjustment cannot meet the current value, the fine adjustment is reset to zero, and the coarse adjustment knob is slowly adjusted.And with fine adjustment until the required current value is reached.
    5. It is recommended to set the cutoff voltage (lower voltage input) when the battery is discharged.In order to avoid damage caused by excessive discharge.
    Interface introduction:
    Note: 150V 10A 150W is the test upper limit, output voltage × input current ≤ 150W
    Product List:
    1*Electronic load host
    1*Power Adapter
    1*Instruction manual
    Payment Mathod
    Returns Policy
    Feedback
    Payment Mathod
    1. Customer satisfaction is our top goal. We believe our items are so outstanding. All products are quality checked. They are new and in good condition when shipped to our customers. We are convinced you will be happy with your Purchase.
    2. If product is defective or damage upon arrival, or wrong product shipped, please contact us immediately. Returns accepted within 14 days of delivery date and item must be in original new condition, not worn or altered in any way with attached tags & wrap. Otherwise deal is final. Return shipping must be paid by buyer.
    3. Please contact us first if you have any problems/questions/concerns. We will be happy to resolve any issues you may have in a cordial and friendly manner.
    4. We appreciate your Postive Feedback, and will do the same in return. DO NOT leave negative feedback without first communication with us. Ple
    Returns Policy
    1. Customer satisfaction is our top goal. We believe our items are so outstanding. All products are quality checked. They are new and in good condition when shipped to our customers. We are convinced you will be happy with your Purchase.
    2. If product is defective or damage upon arrival, or wrong product shipped, please contact us immediately. Returns accepted within 14 days of delivery date and item must be in original new condition, not worn or altered in any way with attached tags & wrap. Otherwise deal is final. Return shipping must be paid by buyer.
    3. Please contact us first if you have any problems/questions/concerns. We will be happy to resolve any issues you may have in a cordial and friendly manner.
    4. We appreciate your Postive Feedback, and will do the same in return. DO NOT leave negative feedback without first communication
    Feedback
    When you satisfied with our product and services please leave us positive feedback.
    If a problem occurs, contact us immediately with any email request. Just contact us using the " Ask the seller a question" link on eBay.We will maill bakc within 24hours
    Welcome to memolines, happy shopping!
    Best Match
    Shop Homepage
    New product
    Feedback
    About us
    LCR-TC1 Transistor Tester
    ESP32-CAM
    MG996R Metal Gear
    TL866II Plus
    Electronic Load Tester
    Voltmeter Ammeter
    New product
    CO2 Sensor Monitor
    MLA-30+receiving antenna
    CO2/TVOC/HCHO Gas Analyzer
    DS213 Oscilloscope
    Battery Spot Welding Pen
    Electric Welding Machine
    Transistor tester
    Specifications:
    PowerVoltage:DC6~12V Interface:DC5.0
    Voltage measure range:0~150V Accuracy:0.05V
    Current adjustable range:0~10A Accuracy:0.05A
    Capacity range:0~999.999Ah Accuracy:0.001Ah
    Cumulative range:0~99999.9Wh Accuracy:0.01Wh
    Measure range:0~2999.9W Accuracy:0.01W
    Impedance range:0~999.9Ω Accuracy:0.01Ω
    Temperature range:0~99℃ Accuracy:1℃
    Max timing :999:59:59 Accuracy:1s
    Fan cooling power:<150W
    Fan control threshold:Temp>40℃
    Standby reminder threshold:<2W/0.5h;
    Timing function:>0.5W start timing
    Input interface: 20A high current occlusion screw column, type A USB,Mini USB, Micro USB, Type-C USB
    Refresh time:>500ms/time
    Measurement rate: 0.5time/s
    Over limit alarm: interface warning and buzzer alarm
    Voltage overrun auto- stops discharge range:0~150V
    Current overrun auto- stops discharge range:0~10A
    Power overrun auto- stops discharge range:0~150W
    Display screen: LCM display
    Size:149×96×80mm/195×105×135mm(package)
    Weight:570g(package)/370g(net weight)
    Consumption:<1.5A
    Operating temp:-10~60℃
    Operating humidity:10~80(No condensation)
    Mode button function description
    :
    1. Click to switch each display interface
    2. The function of the button operation in the 2-4 interface is as follows:
    ①long press all records to clear;
    ②Double-click capacity (Ah) to reset to zero;
    ③three-stroke power (Wh) reset to zero;
    ④four-stroke power (00:00:00) reset to zero;
    ⑤consecutive seven hits at no load, making the current zero accurate in the current temperature environment.Calibration is zeroed for accurate measurement at low currents;Factory reset all parameters.
    3. The operation functions of the buttons under the interfaces 6, 7, 9, 11, and 13 are as follows:
    ①Double-click the parameter value to increase, double-click and long press the parameter to continue to increase;
    ②The value of the three-stroke parameter is reduced, and the length of the three-stroke is continued to decrease.
    How to use
    :
    1. Input voltage × current ≤ 150W;
    2. Turn on the load power supply, and the coarse and fine adjustment knobs will be reset to zero (counterclockwise to the end)
    3. Long press the mode button to clear all data;
    4. Connect to the power supply under test, and use the fine adjustment knob to slowly adjust the discharge current.When the fine adjustment cannot meet the current value, the fine adjustment is reset to zero, and the coarse adjustment knob is slowly adjusted.And with fine adjustment until the required current value is reached.
    5. It is recommended to set the cutoff voltage (lower voltage input) when the battery is discharged.In order to avoid damage caused by excessive discharge.
    Interface introduction:
    Note: 150V 10A 150W is the test upper limit, output voltage × input current ≤ 150W
    Product List:
    1*Electronic load host
    1*Power Adapter
    1*Instruction manual
    Payment Mathod
    Returns Policy
    Feedback
    Payment Mathod
    1. Customer satisfaction is our top goal. We believe our items are so outstanding. All products are quality checked. They are new and in good condition when shipped to our customers. We are convinced you will be happy with your Purchase.
    2. If product is defective or damage upon arrival, or wrong product shipped, please contact us immediately. Returns accepted within 14 days of delivery date and item must be in original new condition, not worn or altered in any way with attached tags & wrap. Otherwise deal is final. Return shipping must be paid by buyer.
    3. Please contact us first if you have any problems/questions/concerns. We will be happy to resolve any issues you may have in a cordial and friendly manner.
    4. We appreciate your Postive Feedback, and will do the same in return. DO NOT leave negative feedback without first communication with us. Ple
    Returns Policy
    1. Customer satisfaction is our top goal. We believe our items are so outstanding. All products are quality checked. They are new and in good condition when shipped to our customers. We are convinced you will be happy with your Purchase.
    2. If product is defective or damage upon arrival, or wrong product shipped, please contact us immediately. Returns accepted within 14 days of delivery date and item must be in original new condition, not worn or altered in any way with attached tags & wrap. Otherwise deal is final. Return shipping must be paid by buyer.
    3. Please contact us first if you have any problems/questions/concerns. We will be happy to resolve any issues you may have in a cordial and friendly manner.
    4. We appreciate your Postive Feedback, and will do the same in return. DO NOT leave negative feedback without first communication
    Feedback
    When you satisfied with our product and services please leave us positive feedback.
    If a problem occurs, contact us immediately with any email request. Just contact us using the " Ask the seller a question" link on eBay.We will maill bakc within 24hours